Basement units must comply with code

Bob Aaron
The Toronto Star
March 16, 2012

When real estate agents prepare offers for a house with a basement apartment, they typically insert a clause stating that “seller does not warrant retrofit status.”

This results in the purchaser taking the risk of getting caught by city inspectors and having to vacate the unit and forfeit rental income.

Agents and sellers seem to think they are sheltered from liability if they do not “warrant” the basement’s so-called retrofit status.

This practice could end in the light of a recent letter to local real estate agents by Toronto Real Estate Board president Richard Silver.

Silver’s letter attempts to end the confusion over what is and what is not a “legal” basement apartment, and what’s missing if there is only partial full compliance.

Silver quotes noted home inspector Carson Dunlop, who reports that achieving a “legal” basement apartment involves five separate issues:

 • Do the local bylaws permit basement apartments?

 • Does the apartment comply with fire code?

 • Does it comply with building code requirements?

 • Does it comply with electrical safety requirements?

 • Has the apartment been “registered?”

Real estate agents frequently use the term “retrofit” to signify whether the basement unit is or is not fully “legal.” But in this context, its use is incorrect, and only refers to fire code — one of the five requirements.

The provincial fire code is a subset of the Ontario building code. The building code applies only to the day the unit was constructed. Only the fire code is retroactive — and this gives rise to the term “retrofit.”

As a result, a unit which does not have a fire retrofit may otherwise comply with the building code, electrical safety requirements and zoning bylaws. It’s all very complicated.

In 1994, the provincial government set new fire code rules with which all basement apartments, new and existing, must comply. A unit upgraded to comply with the fire code is called a “basement retrofit.”

Compliance with the fire code involves four requirements: fire containment, means of escape, fire detection and alarms, and electrical safety.

Drywall separations between the basement and the rest of the house must have a minimum 30-minute fire rating. A separate exit (or fire-separated shared exit) is required. A basement window is acceptable if it meets certain size and location requirements.

Fire safety rules also require installation of smoke alarms in all units in a house. They do not have to be interconnected unless the fire separation to a common exit area does not have a 30-minute rating. Many municipalities also require carbon monoxide detectors.

Once a unit has been inspected and any deficiencies corrected, the fire department will issue a retrofit certificate to verify compliance.

But a unit that has been fully retrofitted may still not comply with zoning, building code and other requirements.

Identifying whether a municipality’s bylaws permit basement apartments is also important when buying a house with a basement unit. Since 1995, municipalities have had the authority to enforce their bylaws with respect to basement apartments; however, units that existed prior to November 1995 are exempt from meeting local bylaw requirements.

Silver notes that the building code, which prescribes minimum requirements for the construction of buildings, for the most part applies only to the day the house was built, and not retroactively.

As a rule, a basement apartment’s minimum ceiling height must be 6 feet 5 inches; its entrance door must be at least 32 inches by 78 inches; bathrooms require either a window or an exhaust fan; and if there is a parking spot for one of the units, there must also be a parking spot for the other unit.

Electrical safety refers to the required inspection by the Electrical Safety Authority.

Buyers of houses with basement units, and agents marketing them, should always insist on evidence that the unit was in existence in 1995. And they should find out whether the unit does or does not comply with the fire code, building code, electrical safety requirements and municipal zoning bylaws.

Full disclosure is of the utmost importance.

Posted on Tuesday, June 4, 2013 at 01:16PM by Registered CommenterElaine in | CommentsPost a Comment | References1 Reference

References (1)

References allow you to track sources for this article, as well as articles that were written in response to this article.

Reader Comments

There are no comments for this journal entry. To create a new comment, use the form below.

PostPost a New Comment

Enter your information below to add a new comment.

My response is on my own website »
Author Email (optional):
Author URL (optional):
Post:
 
All HTML will be escaped. Hyperlinks will be created for URLs automatically.